RJ45 Connector

RJ45 connectors include DIP, SMT, shielded, unshielded, LED, and multi-port configurations, with selection support based on Ethernet requirements, mounting orientation, PCB dimensions, and equipment design.
View:

Cat 5e RJ45 Keystone Inline Coupler

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

RJ 45 Inline Coupler

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

RJ45 Connector 8P8C with Latch Shielded Vertical Type DIP with LEDs

Rated Current: 1.5 AMPS
Rated Voltage: 125VAC
Insulation Resistance: >500MΩ
Dielectric Withstand Voltage: AC 1000V 50Hz or 60Hz for 1 minute
Contact Resistance:

RJ45 Connector with LEDs DIP Type

Rated Current: 1.5 AMPS
Rated Voltage: 125VAC
Insulation Resistance: >500MΩ
Dielectric Withstand Voltage: AC 1000V 50Hz or 60Hz for 1 minute
Contact Resistance:

DIP RJ48/RJ50 Jack 10P10C Shielded Vertical

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

DIP RJ48/RJ50 Jack 10P10C Shielded R/A

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

1x8 Ports DIP RJ45 Jack with LEDs

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

2x2 Ports DIP RJ45 Jack with LEDs

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

DIP RJ45 Jack Unshielded with LEDs R/A

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

DIP RJ45 Jack Unshielded with LEDs Vertical

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

DIP RJ45 Jack Shielded with LEDs R/A

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

DIP RJ45 Jack Shielded with LEDs Vertical

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

SMT RJ45 Jack Unshielded R/A

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

SMT RJ45 Jack Unshielded Vertical

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

SMT RJ45 Jack Shielded Vertical

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

SMT RJ45 Jack Shielded R/A

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

SMT RJ45 Jack with LEDs R/A

Rated current: 1.5A
Rated voltage: 125VAC
Dielectric Withstanding Voltage: 1000V AC for 1 minute.
Insulation Resistance: 500MΩ min.
Contact Resistance: 20mΩ max.
Operating Temperature:
-40°C ~ +80°C.

Slim RJ45 Connector with LEDs Right Angle Type

Rated Current: 1.5 AMPS
Rated Voltage: 125VAC
Insulation Resistance: >500MΩ
Dielectric Withstand Voltage: AC 1000V 50Hz or 60Hz for 1 minute
Contact Resistance:

Slim RJ45 Connector Vertical Type

Rated Current: 1.5 AMPS
Rated Voltage: 125VAC
Insulation Resistance: >500MΩ
Dielectric Withstand Voltage: AC 1000V 50Hz or 60Hz for 1 minute
Contact Resistance:

Dual USB2.0 + RJ45 8P8C Connector

Rated Current: 1.5 AMPS
Rated Voltage: 125VAC
Insulation Resistance: >500MΩ
Dielectric Withstand Voltage: AC 1000V 50Hz or 60Hz for 1 minute
Contact Resistance:

RJ45 Connector 8P8C SMT with LEDs

Rated Current: 1.5 AMPS
Rated Voltage: 125VAC
Insulation Resistance: >500MΩ
Dielectric Withstand Voltage: AC 1000V 50Hz or 60Hz for 1 minute
Contact Resistance:

RJ11 Connector 6P6C Shielded

Rated Current: 1.5 AMPS
Rated Voltage: 125VAC
Insulation Resistance: >500MΩ
Dielectric Withstand Voltage: AC 1000V 50Hz or 60Hz for 1 minute
Contact Resistance: